To match perfume bottle neck sizes with spray pumps, start with the complete neck finish designation and the pump supplier’s matching reference. Then compare the drawings, fit the decorative parts, and test a filled sample assembled with the intended equipment. A listing that says “15 mm” provides a starting point. You still need the fixation type, sealing geometry, and component specifications to place an order.
For a fragrance brand, this check belongs before sample approval. Changing the pump later can affect the collar, cap, dip tube, and filling setup. Request those parts as a matched assembly when you shortlist bottles.
What Perfume Bottle Neck Sizes Tell You
Read the Complete Neck Finish Designation
The neck finish describes the glass geometry where a closure attaches and seals. Keep its full designation on the bottle specification, pump inquiry, and approved sample record. Codes such as FEA15, CV15, and SNI15 help distinguish different interfaces carrying a similar nominal size.
Aptar’s VP4 specification lists several screw, crimp, and snap-on options separately. Its page identifies regional availability as EMEA, so use the listing to understand that pump family’s options and confirm availability for your project with the supplier. Aptar VP4 fragrance pump specifications
Identify Crimp, Screw, and Snap-On Fixation
Use the fixation type to organize your comparison of perfume bottle neck sizes. The following examples come from the VP4 listing and identify the next information to request.
| Fixation | Listed examples | Attachment | Matching information to request |
| Crimp | FEA13, FEA15, FEA17, FEA18, FEA20 | A ferrule is formed around the glass neck bead. | Bottle finish drawing, pump reference, and crimping requirements |
| Screw | CV15, SNI15, 18/400, 20/400 | A threaded closure seats on the specified finish. | Thread geometry, sealing surface, and assembly instructions |
| Snap-on | 13 mm, 15 mm, 17 mm, 18 mm, 20 mm options | A retaining feature engages the matching glass profile. | Exact pump and neck drawings, seating criteria, and retention requirements |
Record bottle capacity separately. A 50 mL or 100 mL designation describes volume. When comparing different shapes or capacities, check the finish on each model’s drawing. MUB’s catalogs provide separate starting points for selecting crimp and screw bottle styles. Garrafas de vidro MUB com crimpagem · MUB screw glass bottles
How to Match an FEA 15 Perfume Pump
Confirm the Bottle Finish and Pump Reference
For a bottle specified as FEA15, ask the pump supplier to identify the exact FEA 15 perfume pump reference offered for that drawing. Include the bottle SKU and drawing revision in the inquiry. Request confirmation of the ferrule, sealing arrangement, and any other components included with the pump.
For example, a supplier response that names a pump model and references your bottle drawing gives you a configuration to sample. Record that pairing on the sample label so everyone evaluating it works from the same specification.
Check the Ferrule and Crimping Setup
Ask the supplier for the crimping instructions and the dimensions to inspect after assembly. Give those requirements to the filling team before the trial. The team should confirm that its tooling suits the pump and bottle combination, then inspect the fitted ferrule and glass neck.
During approval, check for an uneven collar, glass damage, or movement at the attachment. A change in bottle source, pump reference, or crimping setup calls for a review of the approved assembly and relevant sample checks.
Check Perfume Pump Neck Compatibility on the Drawings
Compare the Sealing Surface, Neck Height, and Retention Features
Have the glass and pump suppliers review the drawings together when perfume pump neck compatibility is uncertain. Identify the glass surface that contacts the seal, the height that controls pump seating, and the feature that holds the pump in place. Ask the suppliers to confirm the required dimensions and tolerances.
Calipers can help record accessible dimensions on an existing sample. Measure at the positions shown on the drawing and keep the results with the sample record. For a bottle with no drawing, send the physical sample to the proposed pump supplier for identification and fitting.
Check Threads and Seating on Screw Finishes
For a screw assembly, confirm the thread profile and how the closure seats against the sealing surface. Ask for the specified assembly torque where applicable. If customers will remove the pump for refilling, include repeated opening and resealing in the sample plan.
When evaluating a screw-neck bottle from MUB, request its current neck drawing and the proposed pump reference. If you plan to retain an existing collar or cap, include those parts in the sample request and confirm their fit on the complete assembly. MUB 50 mL screw-neck glass bottle
Fit the Collar, Actuator, and Decorative Cap
Once the pump is seated, fit the decorative collar and cap. Check the cap’s internal clearance, its grip on the intended locating part, and clearance above the actuator. Operate the spray with the collar in place, then replace and remove the cap several times.
Include these parts in the approval sample. Their appearance in separate product photographs gives limited information about how the complete package fits.
Test the Complete Assembly Before a Bulk Order
Set the Dip Tube Length and Check Spray Performance
Specify dip tube length against the bottle’s internal depth and base shape, using the pump supplier’s measurement method. Assemble a sample and check the tube position. Test priming, spray consistency, and product pickup as the fill level falls.
Use the intended fragrance formula for the trial. Record the requested output per actuation separately from perfume bottle neck sizes so the supplier can confirm both requirements.
Inspect Leakage and Closure Retention
Agree on a test plan that reflects expected storage, transport, and use. Inspect for wetness around the neck and pump and check attachment security after handling. For refillable models, repeat the relevant checks after opening and resealing.
Keep sample identity, assembly settings, conditions, and observations in the test record. If a result changes, those details help the supplier investigate the component or process involved.
Approve Production Samples and Record Revisions
Trial samples should represent the parts and assembly process planned for production. Record the approved bottle, pump, ferrule or screw closure, gasket where applicable, dip tube, collar, and cap. Attach the drawing revisions and assembly instructions to the approval.
Ask the supplier to identify any proposed component substitution before it enters the order. Review its effect on fit, filling equipment, and performance against the approved sample.
What to Include in a Bottle and Pump Inquiry
A clear inquiry lets the supplier check perfume pump neck compatibility before quoting a complete set.
| Information | Details to provide or request |
| Garrafa | SKU, nominal capacity, intended fill volume, and current drawing |
| Acabar o pescoço | Full designation, fixation type, and dimensional requirements |
| Pumpa | Exact reference, requested output, and intended fragrance formula |
| Sealing parts | Contact materials and the specified sealing arrangement |
| Dip tube | Cut length, measurement method, and end cut |
| Decorative parts | Collar, actuator, cap, finish, and any locating insert |
| Assembly | Filling equipment, crimp requirements or screw instructions, and inspection criteria |
| Aprovação | Matched samples, test requirements, drawing revisions, and substitution review |
When selecting from MUB’s range, include the bottle model in the request and ask for the proposed pump and decorative parts together. This gives your team a complete sample to assess before approving the bulk order. MUB perfume packaging
Perguntas Frequentemente Fazidas
Will Every 15 mm Pump Fit an FEA 15 Bottle?
Confirm the pump’s complete fixation and neck finish specification. A pump advertised as 15 mm may belong to a screw or snap-on system, while your bottle requires a crimp assembly. Ask for the supplier’s matching reference and check it against the bottle drawing before sampling.
Does a 100 mL Bottle Need an 18 mm Neck?
Check the neck finish specified for the particular bottle model. Capacity alone gives insufficient information to select the pump. For a range with several capacities, record the finish on each drawing and ask whether the same pump reference has been approved across those models.
Can I Match a Pump Using Calipers Alone?
Calipers help you document a sample, but the supplier also needs to confirm the finish profile, sealing arrangement, and tolerances. Obtain a drawing or send a physical sample for fitting. Approve the complete filled assembly using the production components and intended assembly process.